Page 182 - Demo
P. 182
CIRCUIT PROTECTION182 Visit 3lineelectrical.co.uk todayPrices are correct at the time of printing. Errors & omissions excepted.3.ssentials Power.LINEARC FAULT DETECTION DEVICES (AFDDS)%u2022 Combined AFDD & RCBO providing arc fault protection alongside over-current, residual current and over voltage protection.%u2022 Class A 30mA RCD%u2022 B Trip Curve, 6kA short circuit capacity%u2022 Suitable for TN and TT Earthing systems%u2022 Single module 18mm width, fully interchangeable with switched and unswitched neutral RCBOs and single pole MCBs.%u2022 Double pole switching for complete isolation in the event of a fault.MCB B CURVEDescription Code PriceAFDD RCBO B 6A 30ma 1P+N 6KA 1Mod 3LAFDD6B %u00a3155.99AFDD RCBO B 10A 30ma 1P+N 6KA 1Mod 3LAFDD10B %u00a3155.99AFDD RCBO B 16A 30ma 1P+N 6KA 1Mod 3LAFDD16B %u00a3155.99AFDD RCBO B 20A 30ma 1P+N 6KA 1Mod 3LAFDD20B %u00a3155.99AFDD RCBO B 32A 30ma 1P+N 6KA 1Mod 3LAFDD32B %u00a3155.99AFDD RCBO B 40A 30ma 1P+N 6KA 1Mod 3LAFDD40B %u00a3155.99SURGE PROTECTION%u2022 Suitable for use in TN-C-S (PME) / TN-S / and TT networksDescription Code PriceSurge Arrester 1 Mod 1Ph 3LSASP1M %u00a349.26Type 2-3 Surge Protection Kit & MCB 3LSASPKIT %u00a354.73%u2022 For cables %u00f8 1-25mm2%u2022 Trip curve B%u2022 230V - 50/60Hz%u2022 Single Pole%u2022 Din rail mountingDescription Code PriceMCB B Curve 6A 6kA 3LMCB6B %u00a32.90MCB B Curve 10A 6kA 3LMCB10B %u00a32.90MCB B Curve 16A 6kA 3LMCB16B %u00a32.90MCB B Curve 20A 6kA 3LMCB20B %u00a32.90MCB B Curve 25A 6kA 3LMCB25B %u00a35.55MCB B Curve 32A 6kA 3LMCB32B %u00a32.90MCB B Curve 40A 6kA 3LMCB40B %u00a32.90MCB B Curve 50A 6kA 3LMCB50B %u00a32.90MCB B Curve 63A 6kA 3LMCB63B %u00a35.55100A DIN RAIL TERMINALDescription Code Price100A Din Rail Terminal 1 Module 3LDRT100 %u00a37.87Compatible with all Lewden Consumer unit circuit protection devicesNEWPlease contact your local branch for further details.Bi-Directional RCBOs NOW AVAILABLE!AFDDS, MCBS & SURGE PROTECTIONDouble pole switching for complete isolation in the event of a fault. Switch neutral pole significantly reduces the installation and commissioning test time. Bi-directional polarity.Class A residual current protection. Designed and tested for use with Lewden branded distribution boards.Single module 18mm width, fully interchangeable with unswitched neutral RCBOs, AFDD RCBOs, and single pole MCBs. Compact device height 96mm particularly suited to installations where double pole isolation of individual circuits may be required e.g distribution circuits on TT earthing systems, electric vehicle charging circuits etc.Residual current circuit breaker with integral overcurrent protection 6kA short circuit breaking capacity.